MYT Study Studio / Free learning resource
IGCSE Physics Formula Sheet
Levels & boards: IGCSE Physics (Years 10-11) Cambridge International 0625; Pearson Edexcel International GCSE Physics 4PH1. Independent formula revision; check your current syllabus.
Search this IGCSE Physics formula resource by topic, save useful equations and reveal original worked examples. Motion, forces, energy, thermal physics, waves, electricity and nuclear physics are organised into individual cards with notation, conditions and common mistakes.
Made for independent learners in Hong Kong and across the GCC: the UAE (including Abu Dhabi, Dubai and Sharjah), Saudi Arabia, Kuwait, Qatar, Oman and Bahrain. Choose your exam board and syllabus, wherever you study.
Interactive controls are not ready yet. If this message remains after loading, the page script has not completed. Read the study material below; do not rely on inactive buttons. Check that WordPress retained the script and that an optimisation or security rule is not blocking it.
33 formulas
No formulas match. Try another topic or clear the filters.
Average speed
v = s/t
Notation / units: v m/s; s m; t s.
Use when: Distance over elapsed time; t>0.
Worked example and common mistake
90 m in 6 s gives 15 m/s.
Watch out: Speed uses total distance; average velocity uses displacement.
Acceleration
a = (v-u)/t
Notation / units: a m/s^2; velocities m/s; t s.
Use when: Average acceleration over the interval.
Worked example and common mistake
From 4 to 16 m/s in 3 s: a=4 m/s^2.
Watch out: Use change in velocity, not final velocity alone.
Constant-acceleration velocity
v = u+a*t
Notation / units: u and v m/s; a m/s^2.
Use when: Acceleration is constant.
Worked example and common mistake
u=3, a=2, t=4 gives v=11 m/s.
Watch out: This equation is not a general variable-acceleration model.
Constant-acceleration displacement
s = u*t + a*t^2/2
Notation / units: s m; t s.
Use when: Acceleration constant along the chosen axis.
Worked example and common mistake
u=0, a=3, t=4 gives s=24 m.
Watch out: Only the second term includes t squared.
Velocity-displacement relation
v^2 = u^2 + 2*a*s
Notation / units: SI units; sign convention consistent.
Use when: Constant acceleration; time is eliminated.
Worked example and common mistake
u=2, a=3, s=10 gives v^2=64; forward speed=8 m/s.
Watch out: The square-root sign alone does not determine direction.
Resultant force
F = m*a
Notation / units: F N; m kg; a m/s^2.
Use when: Constant mass; F is the net force.
Worked example and common mistake
A 4 kg object at 2.5 m/s^2 has resultant force 10 N.
Watch out: One applied force is not necessarily the resultant force.
Weight
W = m*g
Notation / units: W N; m kg; g N/kg.
Use when: Use the gravitational field strength supplied.
Worked example and common mistake
m=3 kg, g=9.8 gives W=29.4 N.
Watch out: Weight is a force; mass is not measured in newtons.
Momentum
p = m*v
Notation / units: p kg m/s.
Use when: Non-relativistic motion.
Worked example and common mistake
m=0.6 kg, v=5 m/s gives p=3 kg m/s.
Watch out: Include signs when opposite directions are compared.
Impulse
impulse = F*delta(t) = delta(p)
Notation / units: N s, equivalent to kg m/s.
Use when: F constant or interpreted as mean resultant force.
Worked example and common mistake
12 N for 0.5 s changes momentum by 6 kg m/s.
Watch out: Do not use a peak force as the average force without justification.
Moment of a force
moment = F*d_perpendicular
Notation / units: N m.
Use when: Distance perpendicular from pivot to force line.
Worked example and common mistake
20 N at 0.15 m gives 3 N m.
Watch out: Lever length is not always the perpendicular distance.
Pressure
p = F/A
Notation / units: p Pa; F N; A m^2.
Use when: Force normal to the area.
Worked example and common mistake
80 N over 0.02 m^2 gives 4000 Pa.
Watch out: Convert cm^2 by dividing by 10000, not 100.
Liquid pressure difference
delta(p) = rho*g*h
Notation / units: rho kg/m^3; h m.
Use when: Static liquid of uniform density.
Worked example and common mistake
1000 * 9.8 * 0.5 = 4900 Pa.
Watch out: Add atmospheric pressure only when absolute pressure is required.
Density
rho = m/V
Notation / units: rho kg/m^3; m kg; V m^3.
Use when: Uniform sample or average density.
Worked example and common mistake
2 kg in 0.001 m^3 gives 2000 kg/m^3.
Watch out: Volume must be in cubic units.
Hooke law
F = k*x
Notation / units: F N; k N/m; extension x m.
Use when: Within the limit of proportionality.
Worked example and common mistake
k=200 N/m and x=0.03 m gives F=6 N.
Watch out: x means extension, not the spring's total length.
Elastic energy
E = k*x^2/2
Notation / units: E J.
Use when: Spring obeys Hooke law.
Worked example and common mistake
k=200, x=0.1 gives E=1 J.
Watch out: A non-linear force-extension curve requires its actual area.
Work by a parallel force
W = F*s
Notation / units: W J; F N; s m.
Use when: Force constant and parallel to displacement.
Worked example and common mistake
15 N through 4 m gives 60 J.
Watch out: A perpendicular force does no work on that displacement.
Kinetic energy
E_k = m*v^2/2
Notation / units: J; kg; m/s.
Use when: Non-relativistic translation.
Worked example and common mistake
m=2, v=6 gives E_k=36 J.
Watch out: Doubling speed multiplies kinetic energy by four.
Gravitational energy change
delta(E_p) = m*g*delta(h)
Notation / units: J.
Use when: Approximately uniform gravitational field.
Worked example and common mistake
m=2, g=9.8, rise=3 gives 58.8 J.
Watch out: Use height change, not total path length.
Power
P = E/t
Notation / units: P W; E J; t s.
Use when: Average transfer rate.
Worked example and common mistake
600 J in 5 s gives 120 W.
Watch out: Kilowatts must be converted when the rest is SI.
Efficiency
efficiency = useful output / total input * 100%
Notation / units: Both inputs in energy units or both in power units.
Use when: Include all input energy in the denominator.
Worked example and common mistake
Useful 45 J from 60 J gives 75%.
Watch out: A machine cannot produce more useful energy than its total input.
Specific heat capacity
Q = m*c*delta(T)
Notation / units: c J/(kg K); delta(T) K or degrees C.
Use when: No change of state; c approximately constant.
Worked example and common mistake
m=2, c=4200, rise=5 gives 42000 J.
Watch out: The equation does not describe energy during a phase change.
Specific latent heat
Q = m*L
Notation / units: L J/kg.
Use when: Change of state at constant temperature under stated conditions.
Worked example and common mistake
0.2 kg at L=334000 J/kg needs 66800 J.
Watch out: No temperature-rise factor belongs in this equation.
Wave speed
v = f*lambda
Notation / units: v m/s; f Hz; wavelength m.
Use when: A repeating wave in a specified medium.
Worked example and common mistake
f=50 Hz, lambda=0.8 m gives v=40 m/s.
Watch out: Frequency is not the same as period.
Frequency and period
f = 1/T
Notation / units: Hz and s.
Use when: One complete cycle takes T seconds.
Worked example and common mistake
T=0.02 s gives f=50 Hz.
Watch out: Milliseconds must be converted to seconds.
Refractive index
n = sin(i)/sin(r)
Notation / units: Dimensionless; angles measured to normal.
Use when: Light enters a material from air, with the air index approximated as 1.
Worked example and common mistake
i=45 degrees, r=30 degrees gives n about 1.414.
Watch out: Measure angles to the normal, not the surface.
Electric charge
Q = I*t
Notation / units: Q C; I A; t s.
Use when: Current constant or mean over time.
Worked example and common mistake
0.5 A for 120 s transfers 60 C.
Watch out: Two minutes equals 120 s, not 2 s.
Potential difference
V = E/Q
Notation / units: V volts; E J; Q C.
Use when: Energy transferred per charge.
Worked example and common mistake
24 J transferred by 3 C gives 8 V.
Watch out: Voltage is energy per charge, not energy itself.
Resistance
R = V/I
Notation / units: R ohms; V volts; I amperes.
Use when: Ratio at an operating point; constant R needs ohmic behaviour.
Worked example and common mistake
12 V and 0.4 A gives 30 ohms.
Watch out: Do not assume a filament lamp has constant resistance.
Electrical power
P = V*I
Notation / units: P W.
Use when: Use the voltage across and current through the same device.
Worked example and common mistake
12 V and 2 A gives 24 W.
Watch out: Current in another branch is not the device current.
Series resistance
R_total = R1 + R2 + …
Notation / units: Ohms.
Use when: Resistors in one unbranched series path.
Worked example and common mistake
3 ohms and 7 ohms in series give 10 ohms.
Watch out: The same formula does not apply to parallel resistors.
Parallel resistance
1/R_total = 1/R1 + 1/R2 + …
Notation / units: Ohms.
Use when: Ideal parallel branches between the same nodes.
Worked example and common mistake
Two 6-ohm resistors give R_total=3 ohms.
Watch out: The result must be below the smallest positive branch resistance.
Transformer turns ratio
V_p/V_s = N_p/N_s
Notation / units: Voltages and numbers of turns.
Use when: Ideal transformer with alternating supply.
Worked example and common mistake
240 V, 1200 primary turns, 60 secondary turns gives V_s=12 V.
Watch out: The voltage and turns ratios must use the same order.
Half-life count
N = N0 * (1/2)^n
Notation / units: n number of half-lives.
Use when: A single decaying isotope; background handled separately for count rate.
Worked example and common mistake
Starting at 800, after 3 half-lives the expectation is 100.
Watch out: Half-life is not the time for every nucleus to decay.
How to use the IGCSE Physics Formula Sheet
- Choose a topic or enter a formula name, symbol or unit in the search field.
- Open the worked example and check the conditions before substituting values.
- Save difficult formulas for a focused list, test recall, then print or export that list.
A worked example
A 2 kg mass has kinetic energy of 9 J when its speed is 3 m/s: E = 0.5 x 2 x 3 squared = 9 J. Doubling the speed quadruples this energy; doubling the mass only doubles it.
What to check before using your result
- The collection is a revision reference, not an exhaustive Core/Supplement checklist. Check the exact examination syllabus and permitted materials.
- Use consistent units before substitution; a correct formula with incompatible units still gives a wrong result.
- A saved formula is a revision prompt, not evidence that you can apply it to an unfamiliar problem.
Make your next practice session count
Use this result as a starting point, not a label for your ability. Record one error, explain its cause and complete a similar question without the worked answer. Then try a different example to check that you understood the method rather than remembered a number.
For exam-style application, choose the correct board and component in the MYT past-paper directory. For guided explanations, explore subject-specific online tutoring or request a free 30-minute demo.
Questions about this tool
Are these the formulas printed in my examination?
Not necessarily. This page is an original study collection. Check the current official syllabus and authorised formula materials to determine what is supplied in your examination.
How should I revise a formula rather than memorise it?
Cover the equation, define each quantity, state a condition and solve one new example. Then change a quantity and predict how the answer should change before calculating.
Do I need an account or need to send my results?
No account is required by this tool. Its calculations run in your browser. Tools with a Save on this device option store data locally only when you choose it; your browser, device policy and storage settings can affect persistence. Export important records before clearing browser data. This describes the tool, not any separate site analytics or contact-form processing.
Reference sources and scope
MYT provides independent learning resources, not official exam-board certification or school-entry decisions. Formula explanations, diagnostic questions and study plans here are original study aids. Check your current syllabus and official examination instructions before relying on a resource for an assessment.
